SMD marking
66
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.
5 parts are printed 66
Not sure which one you have?
Answer up to 4 quick questions and these 5 parts are ranked, with a meter test that settles it. It works on a dead part too.
BAS40-06WSOT-323Schottky diode, 3 pins, NexperiaSchottky diodeSOT-3233 pinsNexperia
- What it is
- Schottky diode
- Maker
- Nexperia
- Package
- SOT-323
- Pins
- 3
- Details
- General-purpose dual Schottky diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX84-B10SOT-23Zener diode, 3 pins, NexperiaZener diodeSOT-233 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 10 V ±2% voltage regulator (Zener) diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
EIA-96:660603Precision resistor (EIA-96 code), 2 pinsPrecision resistor (EIA-96 code)06032 pinsNot recorded
- What it is
- Precision resistor (EIA-96 code)
- Maker
- Not recorded
- Package
- 0603
- Pins
- 2
- Details
- EIA-96 precision chip resistor, significand 47.5; the printed mark adds a multiplier letter (66A = 475 Ohm, 66B = 4.75 kOhm)
- Source
- Added by hand from a published table
Is it dead?
Ohms range, across it, power off.
Working, it reads
Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.
Dead, it reads
- Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
- Well above its marked value: drifted high.
- On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
- On the board:
- A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
- Compare:
- The same position on another channel usually carries the same value, and so does the matching part on another board.
- Watch for:
- A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2 more parts have no package on record
BAT64-06/WSchottky diode, InfineonSchottky diodeNot recordedNot recordedInfineon
- What it is
- Schottky diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BBY56-02WInfineonNot recordedNot recordedNot recordedInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
45 more parts are printed with a code easy to misread as 66
Printed with a code easy to misread
One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.
BAT54/DGprinted GGSOT-23Schottky diode, 3 pins, NexperiaSchottky diodeSOT-233 pinsNexperia
Printed GG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Schottky diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 30 V Schottky barrier diode, single (DG selection)
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC817printed 6CSOT-23NPN transistor, 3 pins, JSCJNPN transistorSOT-233 pinsJSCJ
Printed 6C on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- NPN transistor
- Maker
- JSCJ
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, NPN, 45 V, 0.5 A
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC817-40printed 6CSOT-23NPN transistor, 3 pins, InfineonNPN transistorSOT-233 pinsInfineon
Printed 6C on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- NPN transistor
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- 45 V, 500 mA NPN small-signal transistor, gain group 40
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC817-40Hprinted 6CSOT-23NPN transistor, 3 pins, Taiwan SemiconductorNPN transistorSOT-233 pinsTaiwan Semiconductor
Printed 6C on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- NPN transistor
- Maker
- Taiwan Semiconductor
- Package
- SOT-23
- Pins
- 3
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC817-40Wprinted 6CSOT-323Transistor, 3 pins, NexperiaTransistorSOT-3233 pinsNexperia
Printed 6C on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Nexperia
- Package
- SOT-323
- Pins
- 3
- Details
- SMD General Purpose NPN Transistors
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC817-40WHprinted 6CSOT-323NPN transistor, 3 pins, Taiwan SemiconductorNPN transistorSOT-3233 pinsTaiwan Semiconductor
Printed 6C on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- NPN transistor
- Maker
- Taiwan Semiconductor
- Package
- SOT-323
- Pins
- 3
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZD27B110Pprinted 6GSOD-123FZener diode, 2 pins, VishayZener diodeSOD-123F2 pinsVishay
Printed 6G on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOD-123F
- Pins
- 2
- Details
- 110 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZD27C110Pprinted G6SOD-123FZener diode, 2 pins, VishayZener diodeSOD-123F2 pinsVishay
Printed G6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOD-123F
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZT52-C3V9printed C6SOD-123Zener diode, 2 pins, NexperiaZener diodeSOD-1232 pinsNexperia
Printed C6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZT52-C6V8printed CCSOD-123Zener diode, 2 pins, NexperiaZener diodeSOD-1232 pinsNexperia
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZT52-C10printed CGSOD-123Zener diode, 2 pins, NexperiaZener diodeSOD-1232 pinsNexperia
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZT52H-A7V5printed G6SOD-123FZener diode, 2 pins, NexperiaZener diodeSOD-123F2 pinsNexperia
Printed G6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123F
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZT52H-A13printed GCSOD-123FZener diode, 2 pins, NexperiaZener diodeSOD-123F2 pinsNexperia
Printed GC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123F
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZT52H-A20printed GGSOD-123FZener diode, 2 pins, NexperiaZener diodeSOD-123F2 pinsNexperia
Printed GG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123F
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZT52H-C75printed C6SOD-123FZener diode, 2 pins, NexperiaZener diodeSOD-123F2 pinsNexperia
Printed C6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123F
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX84-A51printed C6SOT-23Zener diode, 3 pins, NexperiaZener diodeSOT-233 pinsNexperia
Printed C6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 51 V ±1% voltage regulator (Zener) diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX384B22printed 6CSOD-323Zener diode, 2 pins, VishayZener diodeSOD-3232 pinsVishay
Printed 6C on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOD-323
- Pins
- 2
- Details
- 22 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX585-B3V9printed C6SOD-523Zener diode, 2 pins, NexperiaZener diodeSOD-5232 pinsNexperia
Printed C6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-523
- Pins
- 2
- Details
- 3.9 V ±2% voltage regulator (Zener) diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MMSZ4678printed CCSOD-123Zener diode, 2 pins, Taiwan SemiconductorZener diodeSOD-1232 pinsTaiwan Semiconductor
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Taiwan Semiconductor
- Package
- SOD-123
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PMEG2005EJprinted CCSOD-323Schottky diode, 2 pins, NexperiaSchottky diodeSOD-3232 pinsNexperia
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Schottky diode
- Maker
- Nexperia
- Package
- SOD-323
- Pins
- 2
- Details
- 20 V, 0.5 A very low VF MEGA Schottky barrier rectifier
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PMEG4010CEGWprinted G6SOD-123Schottky diode, 2 pins, NexperiaSchottky diodeSOD-1232 pinsNexperia
Printed G6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Schottky diode
- Maker
- Nexperia
- Package
- SOD-123
- Pins
- 2
- Details
- 40 V, 1 A low VF Schottky barrier rectifier
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SD103CM3printed CCSOD-323Schottky diode, 2 pins, Taiwan SemiconductorSchottky diodeSOD-3232 pinsTaiwan Semiconductor
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Schottky diode
- Maker
- Taiwan Semiconductor
- Package
- SOD-323
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMAJ28Aprinted CGSMATVS diode, 2 pins, VishayTVS diodeSMA2 pinsVishay
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Details
- 400 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMF28Aprinted CGSOD-123FTVS diode, 2 pins, VishayTVS diodeSOD-123F2 pinsVishay
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- SOD-123F
- Pins
- 2
- Details
- SMD Transient Voltage Suppressor Diodes
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMF58Aprinted CCSOD-123FESD protection diode, 2 pins, VishayESD protection diodeSOD-123F2 pinsVishay
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Vishay
- Package
- SOD-123F
- Pins
- 2
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SN74LVC1G04DRYprinted CCSONLogic gate, 6 pins, Texas InstrumentsLogic gateSON6 pinsTexas Instruments
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Logic gate
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single Inverter Gate
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SN74LVC1G04DSFprinted CCSONLogic gate, 6 pins, Texas InstrumentsLogic gateSON6 pinsTexas Instruments
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Logic gate
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single Inverter Gate
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SN74LVC1G32DRYprinted CGSONLogic gate, 6 pins, Texas InstrumentsLogic gateSON6 pinsTexas Instruments
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Logic gate
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single 2-Input Positive-OR Gate
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SN74LVC1G32DSFprinted CGSONLogic gate, 6 pins, Texas InstrumentsLogic gateSON6 pinsTexas Instruments
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Logic gate
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single 2-Input Positive-OR Gate
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SN74LVC1G66DRYprinted C6SONAnalog switch, 6 pins, Texas InstrumentsAnalog switchSON6 pinsTexas Instruments
Printed C6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Analog switch
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single Bilateral Analog Switch
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SN74LVC1G66DSFprinted C6SONAnalog switch, 6 pins, Texas InstrumentsAnalog switchSON6 pinsTexas Instruments
Printed C6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Analog switch
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single Bilateral Analog Switch
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
14 more parts have no package on record
AOZ8212BCI-12printed CCESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedNot recordedAlpha & Omega Semiconductor
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AOZ8212BCI-24printed CCESD protection diode, Alpha & Omega SemiconductorESD protection diodeNot recordedNot recordedAlpha & Omega Semiconductor
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BAR63-02Wprinted GGPIN diode, InfineonPIN diodeNot recordedNot recordedInfineon
Printed GG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- PIN diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BAR63-06/Wprinted G6PIN diode, InfineonPIN diodeNot recordedNot recordedInfineon
Printed G6 on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- PIN diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BB565printed CCInfineonNot recordedNot recordedNot recordedInfineon
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC818-40printed 6GTransistor, InfineonTransistorNot recordedNot recordedInfineon
Printed 6G on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BCX68-16printed CCTransistor, InfineonTransistorNot recordedNot recordedInfineon
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BCX69-16printed CGTransistor, InfineonTransistorNot recordedNot recordedInfineon
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ESD113-B1-02ELprinted CCESD protection diode, InfineonESD protection diodeNot recordedNot recordedInfineon
Printed CC on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
LP5907SNX-1.8printed CGLDO regulator, 4 pins, Texas InstrumentsLDO regulatorNot recorded4 pinsTexas Instruments
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 250mA, Low-Noise, Low-IQ LDO
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
LP5907SNX1printed CGLDO regulator, 4 pins, Texas InstrumentsLDO regulatorNot recorded4 pinsTexas Instruments
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 250mA, Low-Noise, Low-IQ LDO
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
LP5907SNX1.8NOPBG4printed CGLDO regulator, 4 pins, Texas InstrumentsLDO regulatorNot recorded4 pinsTexas Instruments
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 250mA, Low-Noise, Low-IQ LDO
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMP28Aprinted CGTVS diode, VishayTVS diodeNot recordedNot recordedVishay
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- TVS diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 400 W TVS diode, unidirectional
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV9061IDPWprinted CGOp-amp, 5 pins, Texas InstrumentsOp-ampNot recorded5 pinsTexas Instruments
Printed CG on the part. Easy to misread as 66. Check that character with a loupe before you order anything.
- What it is
- Op-amp
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 10MHz, RRIO, CMOS Operational Amplifiers for Cost-Sensitive Systems
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Open this in the search to correct a character or try another package.