SMD marking
26in SOT-23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.
4 parts are printed 26
Not sure which one you have?
Answer up to 4 quick questions and these 4 parts are ranked, with a meter test that settles it. It works on a dead part too.
Digital transistor (NPN, resistors built in). What differs:
DTC144ECASOT-233 pins, JSCJ3 pinsJSCJ
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- JSCJ
- Package
- SOT-23
- Pins
- 3
- Details
- Digital transistor (bias resistors built in), NPN
- Source
- From the manufacturer's datasheet
Is it dead?
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
DTC144EKASOT-233 pins, ROHM3 pinsROHM
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- ROHM
- Package
- SOT-23
- Pins
- 3
- Details
- Digital transistor (bias resistors built in), NPN
- Source
- From the manufacturer's datasheet
Is it dead?
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PDTC123ETSOT-233 pins, Nexperia3 pinsNexperia
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 50 V, 100 mA NPN resistor-equipped transistor; R1 = 2.2 kΩ, R2 = 2.2 kΩ
- Source
- From the manufacturer's datasheet
Is it dead?
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
1 more part has no package on record. Nothing rules them out, so they stay.
DTC144EEJSCJNot recordedJSCJ
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- JSCJ
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Digital transistor (bias resistors built in), NPN
- Source
- From the manufacturer's datasheet
Is it dead?
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
11 more parts are printed with a code easy to misread as 26
Printed with a code easy to misread
One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.
BC849Cprinted 2CSOT-23Transistor, 3 pins, NexperiaTransistor3 pinsNexperia
Printed 2C on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- SMD General Purpose NPN Transistors
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BC850Cprinted 2GSOT-23Transistor, 3 pins, NexperiaTransistor3 pinsNexperia
Printed 2G on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- SMD General Purpose NPN Transistors
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX84-B11printed Z6SOT-23Zener diode, 3 pins, NexperiaZener diode3 pinsNexperia
Printed Z6 on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 11 V ±2% voltage regulator (Zener) diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX84-C7V5printed Z6SOT-23Zener diode, 3 pins, NexperiaZener diode3 pinsNexperia
Printed Z6 on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 7.5 V approx. ±5% voltage regulator (Zener) diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX84C7V5printed Z6SOT-23Zener diode, 3 pins, DiotecZener diode3 pinsDiotec
Printed Z6 on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOT-23
- Pins
- 3
- Details
- SMD Planar Zener Diodes
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MMBTA56printed 2GSOT-23Transistor, 3 pins, InfineonTransistor3 pinsInfineon
Printed 2G on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- SMD General Purpose PNP Transistors
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PMBTA56printed 2GSOT-23PNP transistor, 3 pins, NexperiaPNP transistor3 pinsNexperia
Printed 2G on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- PNP transistor
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
4 more parts have no package on record. Nothing rules them out, so they stay.
SMBTA56printed 2GTransistor, InfineonTransistorNot recordedInfineon
Printed 2G on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Transistor
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV70718DQNprinted ZCLDO regulator, 4 pins, Texas InstrumentsLDO regulator4 pinsTexas Instruments
Printed ZC on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 200-mA, Low-IQ, Low-Noise, Low-Dropout Regulator for Portable Devices
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TPS3839G33DQNprinted ZGVoltage supervisor, 4 pins, Texas InstrumentsVoltage supervisor4 pinsTexas Instruments
Printed ZG on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- Voltage supervisor
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 150-nA, Ultralow Power, Supply Voltage Monitor
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
VESD05C1-HD1printed 2GESD protection diode, VishayESD protection diodeNot recordedVishay
Printed 2G on the part. Easy to misread as 26. Check that character with a loupe before you order anything.
- What it is
- ESD protection diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Single-Line ESD-Protection Diode in DFN1006-2A
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
22 more parts have codes that begin with 26
Codes that begin with 26
For a marking with its end worn or burnt off. Each one shows its full printed code.
ATL431AIDBZprinted ZCKSSOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCKS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATL431AQDBZprinted ZCLSSOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCLS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATL431BIDBZprinted ZCT3SOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCT3. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATL431BQDBZprinted ZCJSSOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCJS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATL432AIDBZprinted ZCNSSOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCNS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATL432AQDBZprinted ZCOSSOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCOS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATL432BIDBZprinted ZCPSSOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCPS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ATL432BQDBZprinted ZCQSSOT-23Voltage reference, 3 pins, Texas InstrumentsVoltage reference3 pinsTexas Instruments
Printed ZCQS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 2.5V Low Iq Adjustable Precision Shunt Regulator
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV853MDBZprinted ZGM4SOT-23Voltage supervisor, 3 pins, Texas InstrumentsVoltage supervisor3 pinsTexas Instruments
Printed ZGM4. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Voltage supervisor
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- 3-Pin Voltage Supervisors with Active-Low, Open-Drain Reset
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
13 more parts have no package on record. Nothing rules them out, so they stay.
AONR26309Aprinted 26309AComplementary MOSFET, Alpha & Omega SemiconductorComplementary MOSFETNot recordedAlpha & Omega Semiconductor
Printed 26309A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Complementary MOSFET
- Maker
- Alpha & Omega Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Complementary N+P MOSFET pair (20-60 V)
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board:
- On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SMPZ3926Bprinted 26BZener diode, VishayZener diodeNot recordedVishay
Printed 26B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 11 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
SS26ALHprinted 26ALHSchottky diode, Taiwan SemiconductorSchottky diodeNot recordedTaiwan Semiconductor
Printed 26ALH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Schottky diode
- Maker
- Taiwan Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier schottky
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZ1AH19Bprinted ZCHZener diode, PanjitZener diodeNot recordedPanjit
Printed ZCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZ1AH19B-AUprinted ZCHZener diode, PanjitZener diodeNot recordedPanjit
Printed ZCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZ1AH20Bprinted 2CHZener diode, PanjitZener diodeNot recordedPanjit
Printed 2CH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZ1AH20B-AUprinted 2CHZener diode, PanjitZener diodeNot recordedPanjit
Printed 2CH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZS5120BASprinted ZCHZener diode, PanjitZener diodeNot recordedPanjit
Printed ZCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZS5120BAS-AUprinted ZCHZener diode, PanjitZener diodeNot recordedPanjit
Printed ZCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZS5122BASprinted 2CHZener diode, PanjitZener diodeNot recordedPanjit
Printed 2CH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZS5122BAS-AUprinted 2CHZener diode, PanjitZener diodeNot recordedPanjit
Printed 2CH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZS5224BCHprinted ZCHZener diode, PanjitZener diodeNot recordedPanjit
Printed ZCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PZS5227BCHprinted 2CHZener diode, PanjitZener diodeNot recordedPanjit
Printed 2CH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Open this in the search to correct a character or try another package.