demotest installation
Skip to content

SMD marking

E2in SOD-323

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

Not sure which one you have?

Answer up to 4 quick questions and these 7 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZX384C2V4SOD-323Zener diode, 2 pins, Vishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-323
    Pins
    2
    Details
    2.4 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5232ASSOD-323Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5232AS-AUSOD-323Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5232BSSOD-323Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5232BS-AUSOD-323Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PMEG1020EASOD-323Schottky diode, 2 pins, Nexperia
    What it is
    Schottky diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Details
    2 A ultra low VF Schottky barrier rectifier
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 1 more part has no package on record. Nothing rules them out, so they stay.
    • CESD5V0D7ESD protection diode, JSCJ
      What it is
      ESD protection diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 5 V
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

1 more part is printed with a code easy to misread as E2

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

  • TLV755185PDQNprinted EZLDO regulator, 4 pins, Texas Instruments

    Printed EZ on the part. Easy to misread as E2. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    Texas Instruments
    Package
    Not recorded
    Pins
    4
    Details
    500mA, Low-IQ, Small-Size, Low-Dropout Regulator
    Source
    From the manufacturer's datasheet

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

13 more parts have codes that begin with E2

Codes that begin with E2

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • PJSD05CWprinted EZBSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD05CW-AUprinted EZBSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD12CWprinted EZDSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZD. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD12CW-AUprinted EZDSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZD. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD15CWprinted EZESOD-323ESD protection diode, 2 pins, Panjit

    Printed EZE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD15CW-AUprinted EZESOD-323ESD protection diode, 2 pins, Panjit

    Printed EZE. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD24CWprinted EZFSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD24CW-AUprinted EZFSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZF. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD36CWprinted EZGSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PJSD36CW-AUprinted EZGSOD-323ESD protection diode, 2 pins, Panjit

    Printed EZG. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    ESD protection diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 3 more parts have no package on record. Nothing rules them out, so they stay.
    • DTC113ZEprinted E21Digital transistor (NPN, resistors built in), JSCJ

      Printed E21. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Digital transistor (bias resistors built in), NPN
      Source
      From the manufacturer's datasheet

      Is it dead?

      Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

      Working, it reads

      Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
      • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
      • Base to emitter near 0 Ω: failed short.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
      Watch for:
      On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PJE8472Bprinted E2BMOSFET, Panjit

      Printed E2B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TESDU24Vprinted E24ESD protection diode, Taiwan Semiconductor

      Printed E24. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      ESD protection diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.