SMD marking
DDin SOT-23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.
5 parts are printed DD
Not sure which one you have?
Answer up to 4 quick questions and these 5 parts are ranked, with a meter test that settles it. It works on a dead part too.
AZ23C3V6SOT-23Zener diode, 3 pins, PanjitZener diode3 pinsPanjit
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ 3.6 V
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23C3V6-AUSOT-23Zener diode, 3 pins, PanjitZener diode3 pinsPanjit
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOT-23
- Pins
- 3
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
BZX84B4V7SOT-23Zener diode, 3 pins, DiotecZener diode3 pinsDiotec
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOT-23
- Pins
- 3
- Details
- SMD Planar Zener Diodes
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2 more parts have no package on record. Nothing rules them out, so they stay.
BFN16RF transistor, InfineonRF transistorNot recordedInfineon
- What it is
- RF transistor
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
ESD321DPYESD protection diode, 2 pins, Texas InstrumentsESD protection diode2 pinsTexas Instruments
- What it is
- ESD protection diode
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 2
- Details
- 1-Channel 30kV ESD Protection Diode with Low Capacitance (< 1pF) in 0402 and SOD-523 Packages
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board:
- On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
4 more parts are printed with a code easy to misread as DD
Printed with a code easy to misread
One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.
AZ23C2V4printed DOSOT-23Zener diode, 3 pins, PanjitZener diode3 pinsPanjit
Printed DO on the part. Easy to misread as DD. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOT-23
- Pins
- 3
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23C2V4-AUprinted DOSOT-23Zener diode, 3 pins, PanjitZener diode3 pinsPanjit
Printed DO on the part. Easy to misread as DD. Check that character with a loupe before you order anything.
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SOT-23
- Pins
- 3
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
2 more parts have no package on record. Nothing rules them out, so they stay.
BB857printed OOInfineonNot recordedNot recordedInfineon
Printed OO on the part. Easy to misread as DD. Check that character with a loupe before you order anything.
- What it is
- Not recorded
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TPS7A2033DQNprinted QOLDO regulator, 4 pins, Texas InstrumentsLDO regulator4 pinsTexas Instruments
Printed QO on the part. Easy to misread as DD. Check that character with a loupe before you order anything.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 4
- Details
- 300mA, Ultra-Low-Noise, Low-IQ, High PSRR LDO
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
28 more parts have codes that begin with DD
Codes that begin with DD
For a marking with its end worn or burnt off. Each one shows its full printed code.
AZ23B2V7printed DD1SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD1. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 2.7 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B2V7-Gprinted DD1SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD1. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 2.7 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V0printed DD2SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD2. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V0-Gprinted DD2SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD2. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V3printed DD3SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD3. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3.3 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V3-Gprinted DD3SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD3. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3.3 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V6printed DD4SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD4. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3.6 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V6-Gprinted DD4SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD4. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3.6 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V9printed DD5SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD5. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3.9 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B3V9-Gprinted DD5SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD5. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 3.9 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B4V3printed DD6SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD6. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 4.3 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B4V3-Gprinted DD6SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD6. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 4.3 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B4V7printed DD7SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD7. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 4.7 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B4V7-Gprinted DD7SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD7. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 4.7 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B5V1printed DD8SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD8. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 5.1 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B5V1-Gprinted DD8SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD8. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 5.1 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B5V6printed DD9SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD9. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 5.6 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
AZ23B5V6-Gprinted DD9SOT-23Zener diode, 3 pins, VishayZener diode3 pinsVishay
Printed DD9. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOT-23
- Pins
- 3
- Details
- 5.6 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board:
- On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
MMFTP245Kprinted DQ1SOT-23MOSFET, 3 pins, DiotecMOSFET3 pinsDiotec
Printed DQ1. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- MOSFET
- Maker
- Diotec
- Package
- SOT-23
- Pins
- 3
- Source
- From the manufacturer's datasheet
Is it dead?
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted.
- No body diode at all: failed open.
- On the board:
- On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
9 more parts have no package on record. Nothing rules them out, so they stay.
LMR16006XDDCprinted D02XDC DC converter, 6 pins, Texas InstrumentsDC DC converter6 pinsTexas Instruments
Printed D02X. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- DC DC converter
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 6
- Details
- SIMPLE SWITCHER® 60 V 0.6 A Buck Regulators With High Efficiency ECO Mode
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
LMR16006YDDCprinted D02YDC DC converter, 6 pins, Texas InstrumentsDC DC converter6 pinsTexas Instruments
Printed D02Y. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- DC DC converter
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 6
- Details
- SIMPLE SWITCHER® 60 V 0.6 A Buck Regulators With High Efficiency ECO Mode
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV70012DDCprinted ODOLDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
Printed ODO. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 200-mA, Low-IQ, Low-Dropout Regulator for Portable Devices
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV70015DDCprinted ODPLDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
Printed ODP. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 200-mA, Low-IQ, Low-Dropout Regulator for Portable Devices
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV70018DDCprinted ODKLDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
Printed ODK. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 200-mA, Low-IQ, Low-Dropout Regulator for Portable Devices
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV70028DDCprinted ODLLDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
Printed ODL. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 200-mA, Low-IQ, Low-Dropout Regulator for Portable Devices
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV70030DDCprinted ODMLDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
Printed ODM. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 200-mA, Low-IQ, Low-Dropout Regulator for Portable Devices
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TLV70033DDCprinted ODNLDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
Printed ODN. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- LDO regulator
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 5
- Details
- 200-mA, Low-IQ, Low-Dropout Regulator for Portable Devices
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TMP20AIDRLprinted ODATemperature sensor, 6 pins, Texas InstrumentsTemperature sensor6 pinsTexas Instruments
Printed ODA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.
- What it is
- Temperature sensor
- Maker
- Texas Instruments
- Package
- Not recorded
- Pins
- 6
- Details
- ±2.5°C Low-Power, Analog Out Temperature Sensor
- Source
- From the manufacturer's datasheet
Is it dead?
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Open this in the search to correct a character or try another package.