SMD marking

D1

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

Not sure which one you have?

Answer up to 4 quick questions and these 15 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 1N4148WSOD-123FSwitching diode, 2 pins, Taiwan Semiconductor
    What it is
    Switching diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Details
    Surface-mount fast switching diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BCW31SOT-23NPN transistor, 3 pins, Nexperia
    What it is
    NPN transistor
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZD27C3V9PSOD-123FZener diode, 2 pins, Vishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123F
    Pins
    2
    Details
    3.9 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52-C47SOD-123Zener diode, 2 pins, Nexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-123
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMBZ5226BSOT-23Zener diode, 3 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMBZ5226BTWSOT-363Zener diode, 6 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-363
    Pins
    6
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMBZ5226BWSOT-323Zener diode, 3 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-323
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5226BSOD-123Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-123
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5226B-AUSOD-123Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-123
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5226BSSOD-323Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5226BS-AUSOD-323Zener diode, 2 pins, Panjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PUMD12SOT-363Digital transistor (PNP, resistors built in), 6 pins, Nexperia
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-363
    Pins
    6
    Details
    50 V, 100 mA NPN/PNP resistor-equipped double transistor; R1 = 47 kΩ, R2 = 47 kΩ
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PUMD16SOT-363Digital transistor (PNP, resistors built in), 6 pins, Nexperia
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-363
    Pins
    6
    Details
    50 V, 100 mA NPN/PNP resistor-equipped double transistor; R1 = 22 kΩ, R2 = 47 kΩ
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • RB520S-40SOD-523Schottky diode, 2 pins, JSCJ
    What it is
    Schottky diode
    Maker
    JSCJ
    Package
    SOD-523
    Pins
    2
    Details
    Schottky diode, 40 V, 0.2 A
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 1 more part has no package on record
    • DS520-40A1Schottky diode, JSCJ
      What it is
      Schottky diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky diode, 40 V, 0.2 A
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

16 more parts are printed with a code easy to misread as D1

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

  • AZ23C5V6printed DISOT-23Zener diode, 3 pins, Panjit

    Printed DI on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 5.6 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C5V6-AUprinted DISOT-23Zener diode, 3 pins, Panjit

    Printed DI on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C17printed DLSOT-23Zener diode, 3 pins, Panjit

    Printed DL on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZD27C10P-Mprinted O1SOD-123FZener diode, 2 pins, Vishay

    Printed O1 on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123F
    Pins
    2
    Details
    10 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZD27C68P-Mprinted Q1SOD-123FZener diode, 2 pins, Vishay

    Printed Q1 on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123F
    Pins
    2
    Details
    68 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52-B8V2printed DLSOD-123Zener diode, 2 pins, Nexperia

    Printed DL on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-123
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52H-B5V1printed DLSOD-123FZener diode, 2 pins, Nexperia

    Printed DL on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX384-C30printed DLSOD-323Zener diode, 2 pins, Nexperia

    Printed DL on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PDTA143ETprinted 01SOT-23Digital transistor (PNP, resistors built in), 3 pins, Nexperia

    Printed 01 on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    50 V, 100 mA PNP resistor-equipped transistor; R1 = 4.7 kOhm, R2 = 4.7 kOhm
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PDTA143EUprinted 01SOT-323Digital transistor (PNP, resistors built in), 3 pins, Nexperia

    Printed 01 on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-323
    Pins
    3
    Details
    50 V, 100 mA PNP resistor-equipped transistor; R1 = 4.7 kΩ, R2 = 4.7 kΩ
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • UDZS22Bprinted DLSOD-323Zener diode, 2 pins, Taiwan Semiconductor

    Printed DL on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • EIA-96:01printed 010603Precision resistor (EIA-96 code), 2 pins

    Printed 01 on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

    What it is
    Precision resistor (EIA-96 code)
    Maker
    Not recorded
    Package
    0603
    Pins
    2
    Details
    EIA-96 precision chip resistor, significand 10; the printed mark adds a multiplier letter (01A = 100 Ohm, 01B = 1 kOhm)
    Source
    Added by hand from a published table

    Is it dead?

    Ohms range, across it, power off.

    Working, it reads

    Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

    Dead, it reads

    • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
    • Well above its marked value: drifted high.
    • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
    On the board:
    A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
    Compare:
    The same position on another channel usually carries the same value, and so does the matching part on another board.
    Watch for:
    A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 4 more parts have no package on record
    • TESDA6V0U40P1Q0printed DIESD protection diode, Taiwan Semiconductor

      Printed DI on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

      What it is
      ESD protection diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TLV70731DQNprinted DILDO regulator, 4 pins, Texas Instruments

      Printed DI on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      4
      Details
      200-mA, Low-IQ, Low-Noise, Low-Dropout Regulator for Portable Devices
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPS7A2012DQNprinted QILDO regulator, 4 pins, Texas Instruments

      Printed QI on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      4
      Details
      300mA, Ultra-Low-Noise, Low-IQ, High PSRR LDO
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPS7A2025DQNprinted QLLDO regulator, 4 pins, Texas Instruments

      Printed QL on the part. Easy to misread as D1. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      4
      Details
      300mA, Ultra-Low-Noise, Low-IQ, High PSRR LDO
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

19 more parts have codes that begin with D1

Codes that begin with D1

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • AZ23C6V8printed D11SOT-23Zener diode, 3 pins, Panjit

    Printed D11. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 6.8 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C6V8-AUprinted D11SOT-23Zener diode, 3 pins, Panjit

    Printed D11. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C7V5printed D12SOT-23Zener diode, 3 pins, Panjit

    Printed D12. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 7.5 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C7V5-AUprinted D12SOT-23Zener diode, 3 pins, Panjit

    Printed D12. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C8V2printed D13SOT-23Zener diode, 3 pins, Panjit

    Printed D13. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 8.2 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C8V2-AUprinted D13SOT-23Zener diode, 3 pins, Panjit

    Printed D13. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C9V1printed D14SOT-23Zener diode, 3 pins, Panjit

    Printed D14. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 9.1 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C9V1-AUprinted D14SOT-23Zener diode, 3 pins, Panjit

    Printed D14. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C10printed D15SOT-23Zener diode, 3 pins, Panjit

    Printed D15. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 10 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C10-AUprinted D15SOT-23Zener diode, 3 pins, Panjit

    Printed D15. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C11printed D16SOT-23Zener diode, 3 pins, Panjit

    Printed D16. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 11 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C11-AUprinted D16SOT-23Zener diode, 3 pins, Panjit

    Printed D16. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C12printed D17SOT-23Zener diode, 3 pins, Panjit

    Printed D17. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 12 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C12-AUprinted D17SOT-23Zener diode, 3 pins, Panjit

    Printed D17. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C13printed D18SOT-23Zener diode, 3 pins, Panjit

    Printed D18. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 13 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C13-AUprinted D18SOT-23Zener diode, 3 pins, Panjit

    Printed D18. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C15printed D19SOT-23Zener diode, 3 pins, Panjit

    Printed D19. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 15 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AZ23C15-AUprinted D19SOT-23Zener diode, 3 pins, Panjit

    Printed D19. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOT-23
    Pins
    3
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • EMD10printed D10SOT-563Digital transistor (resistors built in), 6 pins, JSCJ

    Printed D10. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Digital transistor (resistors built in)
    Maker
    JSCJ
    Package
    SOT-563
    Pins
    6
    Details
    Digital transistor (bias resistors built in), NPN PNP
    Source
    From the manufacturer's datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.