Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

Not sure which one you have?

Answer up to 4 quick questions and these 16 parts are ranked, with a meter test that settles it. It works on a dead part too.

The only part printed 8G in this package in our tables

BZD27B130P

What it is
Zener diode
Maker
Vishay
Package
SOD-123F
Pins
2
Details
130 V Zener diode
Source
From the manufacturer's datasheet

Is it dead?

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board:
On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread

These parts are printed with a character that is easy to misread as what you typed. The odd one out is marked on each.

  • BZT52H-C3V3printed B6SOD-123FZener diode, 2 pins, Nexperia

    Printed B6 on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52H-C5V6printed BCSOD-123FZener diode, 2 pins, Nexperia

    Printed BC on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52H-C8V2printed BGSOD-123FZener diode, 2 pins, Nexperia

    Printed BG on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMF13Aprinted BGSOD-123FESD protection diode, 2 pins, Vishay

    Printed BG on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

    What it is
    ESD protection diode
    Maker
    Vishay
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 11 more parts have no package on record. Nothing rules them out, so they stay.
    • BAT68-06printed 86Schottky diode, Infineon

      Printed 86 on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      Schottky diode
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BBY58-06Wprinted B6Infineon

      Printed B6 on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      Not recorded
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BCX71Gprinted BGTransistor, Infineon

      Printed BG on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      Transistor
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BZX884B30Lprinted BGZener diode, Vishay

      Printed BG on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      30 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • MSMP13Aprinted BGTVS diode, Vishay

      Printed BG on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      150 W TVS diode, unidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PEC3205C2Eprinted BCESD protection diode, Panjit

      Printed BC on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      ESD protection diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SMP13Aprinted BGTVS diode, Vishay

      Printed BG on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      400 W TVS diode, unidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SN74AUP1G80DPWprinted BCLogic flip flop, 5 pins, Texas Instruments

      Printed BC on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      Logic flip flop
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      5
      Details
      Low-Power Single Positive-Edge-Triggered D-Type Flip-Flop
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TLV70710PDQNprinted BCLDO regulator, 4 pins, Texas Instruments

      Printed BC on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      4
      Details
      200-mA, Low-IQ, Low-Noise, Low-Dropout Regulator for Portable Devices
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TLV70729PDQNprinted BGLDO regulator, 4 pins, Texas Instruments

      Printed BG on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      LDO regulator
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      4
      Details
      200-mA, Low-IQ, Low-Noise, Low-Dropout Regulator for Portable Devices
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPD1E10B06DPYprinted B6ESD protection diode, 2 pins, Texas Instruments

      Printed B6 on the part. Easy to misread as 8G. Check that character with a loupe before you order anything.

      What it is
      ESD protection diode
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      2
      Details
      Single-Channel ESD Protection Diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

31 more parts have codes that begin with 8G

Codes that begin with 8G

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • PZ1AL3V9B-AUprinted BCHSOD-123FZener diode, 2 pins, Panjit

    Printed BCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 30 more parts have no package on record. Nothing rules them out, so they stay.
    • AOB66216Lprinted B66216MOSFET, Alpha & Omega Semiconductor

      Printed B66216. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOB66613Lprinted B66613MOSFET, Alpha & Omega Semiconductor

      Printed B66613. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOB66616printed B66616MOSFET, Alpha & Omega Semiconductor

      Printed B66616. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOB66620Lprinted B66620MOSFET, Alpha & Omega Semiconductor

      Printed B66620. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOB66811Lprinted B66811MOSFET, Alpha & Omega Semiconductor

      Printed B66811. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOB66916Lprinted B66916MOSFET, Alpha & Omega Semiconductor

      Printed B66916. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOB66919Lprinted B66919MOSFET, Alpha & Omega Semiconductor

      Printed B66919. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOB66920Lprinted B66920MOSFET, Alpha & Omega Semiconductor

      Printed B66920. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ1327DI-01printed BC01Load switch, Alpha & Omega Semiconductor

      Printed BC01. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Load switch
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      USB Type-C protection switch
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground.

      Working, it reads

      Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

      Dead, it reads

      • Output at the input voltage while switched off: the pass element has shorted.
      • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
      On the board:
      An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ1327DI-02printed BC02Load switch, Alpha & Omega Semiconductor

      Printed BC02. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Load switch
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      USB Type-C protection switch
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground.

      Working, it reads

      Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

      Dead, it reads

      • Output at the input voltage while switched off: the pass element has shorted.
      • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
      On the board:
      An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ1328DI-01printed BG01Load switch, Alpha & Omega Semiconductor

      Printed BG01. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Load switch
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      USB Type-C protection switch
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground.

      Working, it reads

      Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

      Dead, it reads

      • Output at the input voltage while switched off: the pass element has shorted.
      • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
      On the board:
      An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ1328DI-02printed BG02Load switch, Alpha & Omega Semiconductor

      Printed BG02. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Load switch
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      USB Type-C protection switch
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, black probe on ground.

      Working, it reads

      Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

      Dead, it reads

      • Output at the input voltage while switched off: the pass element has shorted.
      • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
      On the board:
      An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BCP49printed BCP49Transistor, Infineon

      Printed BCP49. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Transistor
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BCP54printed BCP54Transistor, Infineon

      Printed BCP54. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Transistor
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BCP55printed BCP55Transistor, Infineon

      Printed BCP55. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Transistor
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BGF100printed BGF100RF amplifier (MMIC), Infineon

      Printed BGF100. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      RF amplifier (MMIC)
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, on the output pin that the bias resistor or choke feeds.

      Working, it reads

      The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

      Dead, it reads

      • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
      • Output pin at the full supply voltage: open inside, no current flowing.
      On the board:
      Measured on the board with power on; the bias network is part of the reading.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The figures depend on the part and its bias resistor. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BGF104printed BGF104RF amplifier (MMIC), Infineon

      Printed BGF104. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      RF amplifier (MMIC)
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage, board powered, on the output pin that the bias resistor or choke feeds.

      Working, it reads

      The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

      Dead, it reads

      • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
      • Output pin at the full supply voltage: open inside, no current flowing.
      On the board:
      Measured on the board with power on; the bias network is part of the reading.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The figures depend on the part and its bias resistor. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ8V2Cprinted 8C2Zener diode, Vishay

      Printed 8C2. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      8.2 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZ1AH3V9Bprinted BCHZener diode, Panjit

      Printed BCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZ1AH3V9B-AUprinted BCHZener diode, Panjit

      Printed BCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS514V3BASprinted BCHZener diode, Panjit

      Printed BCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS514V3BAS-AUprinted BCHZener diode, Panjit

      Printed BCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS524V7BCHprinted BCHZener diode, Panjit

      Printed BCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SN74AHCT1G32DRLprinted BGSLogic gate, 5 pins, Texas Instruments

      Printed BGS. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Logic gate
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      5
      Details
      Single 2-Input Positive-OR Gate
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TA6F20Aprinted BGPTVS diode, Vishay

      Printed BGP. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      600 W TVS diode, unidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TA6F20CAprinted BGPTVS diode, Vishay

      Printed BGP. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      600 W TVS diode, bidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TA6L20Aprinted BGLTVS diode, Vishay

      Printed BGL. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      600 W TVS diode, unidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TA6L20CAprinted BGLTVS diode, Vishay

      Printed BGL. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      600 W TVS diode, bidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPSMA6L13Aprinted BGATVS diode, Diotec

      Printed BGA. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      TVS diode
      Maker
      Diotec
      Package
      Not recorded
      Pins
      Not recorded
      Details
      SMD Transient Voltage Suppressor Diodes
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPSMP20Aprinted BGPTVS diode, Vishay

      Printed BGP. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      400 W TVS diode, unidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.